EasyManuals Logo

Datamax A-4310 User Manual

Default Icon
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #65 background imageLoading...
Page #65 background image
Extended System-Level Command Functions
Class Series Programmer’s Manual 49
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Media Settings
Head Cleaning
HC
0 – 9999
Inches (or centimeters)
multiplied by 1000
EX2 N/A
N/A
Display-Equipped Print Control
Non-Display 23
Heat
HE
0 – 30 N/A
M1 & M2
Non-Display
21
Hnn
Display-Equipped Communications
Host Timeout
HT
1 – 60 Seconds
EX2 N/A
N/A
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Ignore Control Codes
IC
1, 0
1 = Enabled,
0 = Disabled
Non-Display N/A
N/A
Ignore Distances
IE
1, 0
1 = Enabled,
0 = Disabled
Non-Display N/A N/A
Display-Equipped System Settings
EX2 N/A
Imaging Mode
IL
M, S
M = Multiple label,
S = Single label
M1 & M2
Non-Display
22
N/A
Table 5-1: Configuration Set Commands (continued)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax A-4310 and is the answer not in the manual?

Datamax A-4310 Specifications

General IconGeneral
BrandDatamax
ModelA-4310
CategoryPrinter
LanguageEnglish

Related product manuals