Extended System-Level Command Functions
Class Series Programmer’s Manual 49
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Display-Equipped Media Settings
Head Cleaning
HC
0 – 9999
Inches (or centimeters)
multiplied by 1000
EX2 N/A
N/A
Display-Equipped Print Control
Non-Display 23
Heat
HE
0 – 30 N/A
M1 & M2
Non-Display
21
Hnn
Display-Equipped Communications
Host Timeout
HT
1 – 60 Seconds
EX2 N/A
N/A
Y, N
Y = Enabled,
N = Disabled
Display-Equipped Communications
Ignore Control Codes
IC
1, 0
1 = Enabled,
0 = Disabled
Non-Display N/A
N/A
Ignore Distances
IE
1, 0
1 = Enabled,
0 = Disabled
Non-Display N/A N/A
Display-Equipped System Settings
EX2 N/A
Imaging Mode
IL
M, S
M = Multiple label,
S = Single label
M1 & M2
Non-Display
22
N/A
Table 5-1: Configuration Set Commands (continued)