Extended System-Level Command Functions
Class Series Programmer’s Manual 51
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Language Select
LS
String Language Name Display-Equipped System Settings N/A
Display-Equipped System Settings
N, A, P, L
M1 & M2
Non-Display
20
Legacy Emulation
LE
N, A, P, L, M
N = None,
A = Allegro,
P = Prodigy,
L = Prodigy Plus,
M = Prodigy Max
X = XL
Non-Display 22
N/A
Display-Equipped Media Settings
Mark Value
MV
0 – 255 N/A
EX2 N/A
N/A
Maximum Length Ignore
SM
0, 1
0 = Processed normally,
1 = Ignore
Display-Equipped Communications N/A
Display-Equipped Media Settings
Maximum Length
ML
0 – 9999 1/100 inch
EX2 N/A
<STX>M
Display-Equipped Media Settings
M1 & M2
Non-Display
N/A
Media Type
MT
D, T
D = Direct,
T = Thermal Transfer
Non-Display
1
<STX>KD
Menu Mode
MM
U, A
U = User,
A = Advanced
Display-Equipped System Settings N/A
Table 5-1: Configuration Set Commands (continued)