Extended System-Level Command Functions
52 Class Series Programmer’s Manual
<STX>Kc
Parameter Name
Parameter
Pneumonic
Value /
Range
Units /
Interpretation
Applicable
Printer Type
Menu Item Equivalent
or Menu Item Number
Command
Equivalent
Z, G Display-Equipped
Module Command
MCC
B
See Table 5-4.
EX2
N/A N/A
Display-Equipped N/A
Network Setup
NT
D, G, I, N, P,
S, T, U, w,
W, Y, Z
See Table 5-5.
EX2 N/A
N/A
No Paper Min
[2]
(Out Of Stock)
TN
0 – 16 .1 Volt DC Non-Display 11 N/A
No Reprint
NR
Y, N
Y = Enabled,
N = Disabled
Non-Display 26 N/A
Option Feedback
OF
D, Rx, S See Table 5-6. Display-Equipped Communications N/A
Display-Equipped Media Settings
Paper Empty
PO
0 – 9999 1/100 inch
EX2 N/A
N/A
Display-Equipped Media Settings
Paper Value
PV
0 – 255 N/A
EX2 N/A
N/A
Table 5-1: Configuration Set Commands (continued)