EasyManua.ls Logo

Datamax A-4310 - Page 95

Default Icon
302 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Extended System-Level Command Functions
Class Series Programmer’s Manual 79
(RD) Reflective TOF Delta – This command allows the manual entry for the control of the low-
level voltage difference level to recognize a label “gap” or “mark.”
(RE) Ribbon Saver Equipped – This command allows the printer to sense the ribbon saver
option. A or Y - automatically senses device presence; if undetected, no error is generated. E -
enables the device, where its presence must be detected; otherwise, a fault is generated. N or D -
disables device detection. See <STX>R for command details.
(RF) Row Adjust Fine Tune – This command shifts the vertical start of print position in dots (see
Appendix K) upward or downward to fine-tune the Row Offset setting to compensate for slight
mechanical differences sometimes evident if multiple printers share label formats.
(RG) Reflective TOF Gain – This command allows the manual entry for the control of the
voltage to the LED emitter of the Media Sensor.

Table of Contents

Related product manuals