Configuration Using a Static IP Address
Once the Ethernet Print Sever has been installed, p
lug in the power cord, but do not connect the Ethernet cable, then turn
the printer’s power switch ‘On’.
1. Verify the printer is in the ‘Ready Mode’
!
XFE!21;27B!13KVM3114!
SFBEZ!
2. Press the
MENU
button to enter the printer’s menu.
NFOV!NPEF!
NFEJB!TFUUJOHT!
3. Using the
FWD
button scroll to
‘COMMUNICATIONS’ and
press the
button.
NFOV!NPEF!
DPNNVOJDBUJPOT!
4. Using the
FWD
button scroll to
‘NIC ADAPTER’ and press the
button.
DPNNVOJDBUJPOT!
OJD!BEBQUFS!
5. Using the
FWD
button scroll to
‘IP DISCOVERY’ and press the
button.
OJD!BEBQUFS!
JQ!EJTDPWFSZ!
6. Using the
FWD
button scroll to
‘DISABLED’ and press the
button.
JQ!EJTDPWFSZ!
+EJTBCMFE!
7. Press the button once to return to the ‘NIC ADAPTER’
menu level. Then use the
FWD
button scroll to
‘IP ADDRESS’
and press the button.
OJD!BEBQUFS!
JQ!BEESFTT!

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datamax M-Class and is the answer not in the manual?

Datamax M-Class Specifications

General IconGeneral
Print MethodThermal Transfer/Direct Thermal
Resolution203 dpi, 300 dpi
Print Speed6 IPS (152 mm/s)
InterfaceUSB, Serial, Ethernet, Parallel
Media SensorReflective and Transmissive
Supported Media TypesLabels, Tags
Media Thickness0.0025" (0.0635 mm)