Technical Manual
58
Maintenance
NOTE:
Appropriate safe working practices should be followed to ensure that
all hazards are minimised.
When the system is in operation, the inverter pod should be washed down
with clean, salt-free water whenever it is returned to the deck of the ship.
This will reduce corrosion, and enable thorough inspection of all the main
housing, connectors, and connecting cables.
It is good working practice to regularly check all clamp fastenings to ensure
they are present, tight, and there is no damage to them or the items they are
fitted to. Any damaged fastenings should be replaced immediately.
The electrical cable connected to the inverter pod should be visually inspected
to ensure there are no chafes or cut in the insulation. The connectors on both
ends of the cable should be tightly fitted, and the lock-rings should be finger-
tight. Any damaged cables or lock-rings should be replaced immediately.