Technical Manual
94
Cone Up Condition Sensor Output Software Control
Cone is Up Open Circuit Cone Up
Broken Cable Open Circuit Cone Up
Will fail in thrust after 4seconds
Will not retract in Engineering or
Job Screen
Cone is Out Closed Circuit Cone Out
Cone Up Misaligned Open Circuit Screen shows Cone Up
Will fail in thrust after 4 seconds
Will not retract in Engineering or
Job Screen
Will stop if misalignment occurs
during job (only resolution is to
use manual inverter)
Assembly
An exploded view of the cone up sensor arrangement is illustrated in Drawing
1686-03b-ASS, which can be found on the following page. This drawing
provides a representation of the main parts that make up the assembly, and
the way in which they fit together.
There are no user serviceable parts in the cone up sensor unit. Please return
unit to Datem for service/repair.
When ordering any replacement parts, please quote the assembly drawing
number, revision, and title, followed by the item number and description of
the part you wish to order.