Part Number GA_SM 08/18 37
Service Screens
Operator screens are covered in Section 3, Operation.
The manager password is 211276.
FRAME HEATER FREEZER ONLY
Frame Heater
Back
Always OffAlways on Power Save
!
Configuration Screen\Frame Heater
• Access to this page requires the manager password.
• The selected mode/button will be gray.
• These buttons control the length of time that heat is
applied to the door perimeter.
• Selecting the Always On icon switches the frame heater
to be on at times when the unit is on. Use this mode
if excessive condensation is observed on the door
opening.
• Selecting the Always Off icon switches the frame heater
to be off at all times.
• Selecting the Power Save icon switches the frame
heater to be on only when the compressor is on. Power
save mode will use less energy than always on while
occasionally heating the door to remove condensation.
This is the factory default.
RAPID PULL DOWN REFRIGERATOR ONLY
Configuration Screen\Rapid Pull Down
• Access to this page requires the manager password.
• When the rapid pull down is turned on the set point is
lowered to 30°F for 60 minutes.
• It can be turned off any time during the 60 minutes of
rapid pull down.
• Selecting this Icon switches the rapid pull down feature
between Off and On.
Rapid Pull Down Feature is Off
Rapid Pull Down Feature is On
Section 6
Control