Number Severity Description/Recommended actions
No action is required.
273 Info. PHY fault isolation has been enabled or disabled by a user for the indicated enclosure and controller module.
Recommended actions:
No action is required.
274 Warning The indicated PHY has been disabled, either automatically or by a user. Drive PHYs are automatically disabled
for empty disk slots or if a problem is detected. The following reasons indicate a likely hardware fault:
Disabled because of error count interrupts
Disabled because of excessive PHY change counts
PHY is ready but did not pass COMINIT
Recommended actions:
If none of the reasons listed above, no action is required.
If any of the reasons listed above is indicated and the event occurs shortly after the storage system is
powered up, do the following:
Shut down the Storage Controllers. Then turn o the power for the indicated enclosure wait a few
seconds, and turn it back on.
If the problem recurs and the event message identies a disk slot, replace the disk in that slot.
If the problem recurs and the event message identies a module, do the following:
If the indicated PHY type is Egress, replace the cable in the module's egress port
If the indicated PHY type is Ingress, replace the cable in the module's ingress port
For other indicated PHY types or if replacing the cable does not x the problem, replace the
indicated module.
If the problem persists, check for other events that may indicate faulty hardware, such as an event
indicating an over-temperature condition or power supply fault, and follow the recommended actions
for those events.
If the problem persists, the fault may be in the enclosure midplane. Replace the chassis FRU.
If any of the reasons listed above is indicated and this event is logged shortly after a failover, user-initiated
rescan, or restart, do the following:
If the event message identies a disk slot, reseat the disk in that slot.
If the problem persists after reseating the disk, replace the disk.
If the event message identies a module, do the following:
If the indicated PHY type is Egress, replace the cable in the module's egress port.
If the indicated PHY type is Ingress, replace the cable in the module's ingress port.
For other indicated PHY types or if replacing the cable does not x the problem, replace the
indicated module.
If the problem persists, check for other events that may indicate faulty hardware, such as an event
indicating an over-temperature condition or power supply fault, and follow the recommended actions
for those events.
If the problem persists, the fault may be in the enclosure midplane. Replace the chassis FRU.
275
Info. The indicated PHY has been enabled.
Recommended actions:
No action is required.
298 Warning The controller's real-time clock (RTC) setting is invalid.
This event will most commonly occur after a power loss if the real-time clock battery has failed. The time may
have been set to a time that is up to 5 minutes before the power loss occurred, or it may have been reset to
1980-01-01 00:00:00.