Number Severity Description/Recommended actions
Recommended actions:
• Check the system date and time. If either is incorrect, set them to the correct date and time.
• Also look for event 246 and follow the recommended action for that event.
When the problem is resolved, event 299 is logged.
299 Info. The controller's RTC setting was successfully recovered.
This event will most commonly occur after an unexpected power loss.
Recommended actions:
• No action is required, but if event 246 is also logged, follow the recommended action for that event.
300 Info. CPU frequency has changed to high.
Recommended actions:
• No action is required.
301 Info. CPU frequency has changed to low.
Recommended actions:
• No action is required.
302 Info. DDR memory clock frequency has changed to high.
Recommended actions:
• No action is required.
303 Info. DDR memory clock frequency has changed to low.
Recommended actions:
• No action is required.
304 Info. The controller has detected I
2
C errors that may have been fully recovered.
Recommended actions:
• No action is required.
305 Info. A serial number in Storage Controller (SC) ash memory was found to be invalid when compared to the serial
number in the controller-module or midplane FRU ID SEEPROM. The valid serial number has been recovered
automatically.
Recommended actions:
• No action is required.
306 Info. The controller-module serial number in Storage Controller (SC) ash memory was found to be invalid when
compared to the serial number in the controller-module FRU ID SEEPROM. The valid serial number has been
recovered automatically.
Recommended actions:
• No action is required.
307 Critical A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller
to shut down.
Recommended actions:
108 Events and event messages