EasyManua.ls Logo

Dell EMC PowerEdge C6420 - M.2 SSD Module; Removing the M.2 SATA X16 Riser; Installing the M.2 SATA X16 Riser

Dell EMC PowerEdge C6420
135 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
M.2 SSD module
The BOSS card is a simple RAID solution card designed specically for booting a server's operating system. The card supports up to two 6
Gbps M.2 SATA drives. The BOSS adapter card has a x8 connector using PCIe gen 2.0 x2 lanes, available only in the low-prole and half-
height form factor.
Removing the M.2 SATA x16 riser
Prerequisites
1 Follow the safety guidelines listed in Safety instructions.
2 Follow the procedure listed in Before working inside your enclosure.
3 Remove the sled from the enclosure.
Steps
1 Using the Phillips #1 screwdriver, loosen the screw that secures the riser to the sled.
2 Lift the riser up to disengage the riser from the connector on the system board.
3 Disconnect the data cable from the riser.
Figure 60. Removing the M.2 SATA x16 riser
Next step
Install the M.2 SATA x16 riser.
Installing the M.2 SATA x16 riser
Prerequisite
1 Follow the safety guidelines listed in Safety instructions.
Installing and removing enclosure components
111

Table of Contents

Other manuals for Dell EMC PowerEdge C6420

Related product manuals