Figure 86. 16 x 2.5 inch SAS/SATA with FPERC12 + 8 x U.2 Gen4
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 81. 16 x 2.5 inch SAS/SATA with FPERC12 + 8 x U.2 Gen4
Order From To
1 SIG_PWR_0 (system board power
connector)
BP_PWR_1 (backplane power
connector)
2 SIG_PWR_2 (system board power
connector)
BP_PWR_1 (backplane power
connector)
3 SL8_CPU1_PA4 (signal connector on
system board)
DST_PB2 (backplane signal connector)
4 SL7_CPU1_PB4 (signal connector on
system board)
DST_PA2 (backplane signal connector)
5 SL4_CPU1_PB2 (signal connector on
system board)
DST_PA1 (backplane signal connector)
6 SL2 _CPU1_PB2 (signal connector on
system board)
DST_PB1 (backplane signal connector)
7 SL3_CPU1_PB2 (signal connector on
system board)
CTRL_DST_PB1 (fPERC input
connector)
8 SL1_CPU1_PB2 (signal connector on
system board)
CTRL_DST_PA1 (fPERC input
connector)
9 SIG_PWR_1 (system board power
connector)
BP_PWR_1 (backplane power
connector)
10 CTRL_SRC_SA1 (fPERC controller
connector)
BP_DST_SA1 (backplane signal
connector)
11 CTRL_SRC_SB1 (fPERC controller
connector)
BP_DST_SA1 (backplane signal
connector)
124 Installing and removing system components