Figure 87. 24 x 2.5 inch SAS/SATA with FPERC11
NOTE:
Follow the sequential order as shown in the table to remove the cables, to install the cables follow the reverse
sequential order.
Table 82. 24 x 2.5 inch SAS/SATA with FPERC11
Order From To
1 SIG_PWR_2 (system board power
connector)
BP_PWR_2 (backplane power
connector)
2 SL1_CPU1_PA4 (signal connector on
system board)
CTRL_DST_PA1 (fPERC input
connector)
3 SIG_PWR_1 (system board power
connector)
BP_PWR_1 (backplane power
connector)
4 CTRL_SRC_SB1 (fPERC controller
connector)
BP_DST_SB1 (backplane signal
connector)
5 CTRL_SRC_SA1 (fPERC controller
connector)
BP_DST_SA1 (backplane signal
connector)
Installing and removing system components 125