Drive-status indicator pattern (RAID only) Condition
Flashes green for three seconds, amber for three seconds, and
then turns o after six seconds
Rebuild stopped
SSD LED indicator pattern
Figure 6. SSD LED indicator pattern
1
SSD activity indicator 2 SSD status indicator
3 SSD
While the operating system is running, the status indicator provides the current status of the device. The following table lists the device
states along with the associated LED indicator codes.
Table 5. SSD LED indicator pattern
State Name Slot/Device State Status LED (Green) Status LED (Amber)
Device status o The system or device is not
powered up.
O O
Device online The device is powered up. On O
Device identify (blink) The device is identifying the slot
location or is indicating that the
device has received a Prepare
for Removal command from the
host operating system.
On for 250 msec
O for 250 msec
O
Device failed The host operating system no
longer has access to the device
because the device is not
responding or has encountered a
critical error condition.
O
On for 250 msec
O for 250 msec
16 About the PowerEdge R930