Memory Mode System Capacity
(in GB)
DIMM Size
(in GB)
Number of
DIMMs
DIMM Slot Population for CPU 1 (Riser A)
Optimized
Population
(Independent
Channel)
32 8 4 X X
48 8 6 X X X
64 8 8 X X X X
80 8 10 X X X X X
96 16 6 X X X
128 16 8 X X X X
96 16 6 X X X
128 16 8 X X X X
192 32 6 X X X
256 32 8 X X X X
192 32 6 X X X
256 32 8 X X X X
384 32 12 X X X X X X
Mirroring and
Partial Mirroring
64 8 8 X X X X
128 8 16 X X X X X X X X
192 8 24 X X X X X X X X X X X X
128 16 8 X X X X
256 16 16 X X X X X X X X
384 16 24 X X X X X X X X X X X X
256 32 8 X X X X
512 32 16 X X X X X X X X
768 32 24 X X X X X X X X X X X X
NOTE: The table displays sample memory propulation for Riser A, the same rules have to be replicated on Riser B.
Memory riser
Removing a memory riser blank
Prerequisites
CAUTION
: Many repairs may only be done by a certied service technician. You should only perform troubleshooting and simple
repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that came with the product.
1 Follow the safety guidelines listed in the Safety instructions section.
2 Follow the procedure listed in the Before working inside your system section.
Step
Holding the slots on the memory riser blank, lift the memory riser blank out of the memory riser and fan cage.
70
Installing and removing system components

Table of Contents