Multec 3.5 Fuel Injector Application Manual Product Description
Delphi Energy and Chassis Systems
Revision: 11/05-1 3-19
Example:
Min flow = 0.46 gm/sec @ (400 kPa fuel pressure + 50 kPa Vac=450
kPa injector pressure drop.)
Max flow = 3.68 g/s @ (400 kPa fuel pressure – 0 kPa Vac = 400 kPa
injector pressure drop.)
Min flow adjusted =
450
400
*46.0
= 0.434
Adjusted flow range requirement = 3.68/0.434 = 8.5