Multec 3.5 Fuel Injector Application Manual Product Description
Delphi Energy and Chassis Systems
Revision: 11/05-1 3-39
SOLENOID COIL SPECIFICATIONS (Nominal)
Coil resistance (ohms @ 20
o
C and 100 µA) 12.0
Temperature coefficient of resistance (1/
o
C) 0.00393
Inductance 6.6 mH @ 1 kHz
Avalanche Energy (steady state) 2.8 mJ @16 V
Maximum intermittent operating voltage at 85
o
C
(100 ms PW / 200 ms Period for 1 minute while
flowing pressurized fuel)
26.5 V
Note: Operation can be temporarily compromised during an over voltage
condition.
Table 3-1 Solenoid Electrical Properties
.
3.16 Environmental Conditions
The Multec 3.5 Fuel Injector is designed to operate in a certain range of
conditions but can withstand extreme operating conditions for short
periods of time. Table 3-2 lists typical examples of normal and extreme
operating conditions. Refer to the Engineering Product Specification for
the application for exact values and conditions. Values shown are for
example purposes only. Specific application values may vary. Extreme
operating conditions are for short durations only with possible degraded
performance.
OPERATING CONDITIONS
Normal Extreme*
Ambient air temperature -40 to +50
o
C -40 to 66
o
C
Underbody air temperature -30 to +90
o
C
Underhood air temperature -40 to +125
o
C -40 to 150
o
C
Relative humidity 0 to 95% @ 85
o
C
Barometric pressure 55 to 105 kPa
Fuel system pressure (nominal) 200* to 500 kPa
Fuel temperature -40 to +65
o
C
Engine intake manifold absolute
pressure
5 to 105 kPa
Table 3-2 - Injector Environmental Operating Conditions
Note:
* Dependent on high temperature performance requirements.
3.16.1 Hot Fuel Handling
See Section 8.4.1 for details on injector hot fuel handling testing and
injector performance.