Chapter 8 Parameters ASDA-A2
8-88 Revision February, 2017
P1-76 AMSPD
Maximum Rotation of Encoder Output Setting
(OA, OB)
Address: 0198H
0199H
Operational
Interface:
Panel / Software Communication
Related Section:
P1-46
Default:
5500
Control
Mode:
ALL
Unit:
r/min
Range:
0 ~ 6000
Data Size:
16-bit
Format:
Decimal
Settings:
A
ccording to the real application, this parameter is set for the maximum
speed and the servo drive will generate smooth function automatically
for encoder output signals.
When the value is set to 0, the function is disabled.
P1-77 ~
P1-80
Reserved
P1-81 VCM2 Max. Speed of 2
nd
Analog Speed Command
Address: 01A2H
01A3H
Operational
Interface:
Panel / Software Communication
Related Section:
P1-40
Default:
Motor rated speed
Control
Mode:
S/T
Unit:
rpm/10V
Range:
0 ~ 50000
Data Size:
32-bit
Format:
Decimal
Settings:
Please refer to the description of P1-40.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals