EasyManuals Logo

Delta ASDA-A2 Series User Manual

Delta ASDA-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #398 background imageLoading...
Page #398 background image
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-147
P4-xx Diagnosis Parameters
P4-00
ASH1 Fault Record (N)
Address: 0400H
0401H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET.
P4-01
ASH2 Fault Record (N-1)
Address: 0402H
0403H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.1
Default
0
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Hexadecimal
Settings
The last second abnormal status record
Low word: LXXXX: display ALM number
High word: hYYYY: display the error code corresponds to CANopen /
DMCNET

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals