ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-107
Settings
1~50Hz: Low stiffness, low response
51~250Hz: Medium stiffness, medium response
251~850Hz: High stiffness, high response
851~1000Hz: Extremely high stiffness, extremely high response
NOTE
1According to the speed loop setting of P2-31, the servo drive sets
the position loop response automatically.
2The function is enabled via parameter P2-32. Please refer to
Chapter 5.6 for corresponding bandwidth size of the setting value.
P2-32
AUT2 Tuning Mode Selection
Address: 0240H
0241H
Operational
Interface
Panel / Software Communication
Related Section:
5.6 and 6.3.6
Default
0
Control
Mode
ALL
Unit
-
Range
0 ~ 0x2
Data Size
16-bit
Format
Hexadecimal
Settings
0: Manual Mode
1: Auto Mode (continuous adjustment)
2: Semi-auto Mode (non- continuous adjustment)

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals