Chapter 8 Parameters ASDA-A2
8-112 Revision February, 2017
P2-40 EDI13 Extended EDI13 Functional Planning
Address: 0250H
0251H
Operational
Interface
Panel / Software Communication
Related Section:
Table 8.1
Default
-
Control
Mode
ALL
Unit
-
Range
0 ~ 0x015F (the last two codes are EDI code)
Data Size
16-bit
Format
Hexadecimal
Settings
Please refer to the description of P2-36
P2-41 EDI14 Extended EDI14 Functional Planning
Address: 0252H
0253H
Operational
Interface
Panel / Software Communication
Related Section:
Table 8.1
Default
-
Control
Mode
ALL
Unit
-
Range
0 ~ 0x015F (the last two codes are EDI code)
Data Size
16-bit
Format
Hexadecimal
Settings
Please refer to the description of P2-36
P2-42 Reserved

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals