Chapter 8 Parameters ASDA-A2
8-152 Revision February, 2017
P4-08
PKEY Input Status of the Drive Keypad (Read-only)
Address: 0410H
0411H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
-
Control
Mode
ALL
Unit
-
Range
(read-only)
Data Size
16-bit
Format
Hexadecimal
Settings
The aim is to check if the five Keys, MODE, UP, DOWN, SHIFT and
SET can work normally. This parameter is also used to check if the
Keys are all functional when producing servo drives.
P4-09
MOT Digital Output Status (Read-only)
Address: 0412H
0413H
Operational
Interface
Panel / Software Communication
Related Section:
4.4.5
Default
-
Control
Mode
ALL
Unit
-
Range
0 ~ 0x1F
Data Size
16-bit
Format
Hexadecimal
Settings
Note: There is no difference whether read by panel or communication.
P4-10
CEN Adjustment Selection
Address: 0414H
0415H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
-

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals