EasyManuals Logo

Delta ASDA-A2 Series User Manual

Delta ASDA-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #427 background imageLoading...
Page #427 background image
Chapter 8 Parameters ASDA-A2
8-176 Revision February, 2017
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-34 AC14 Acceleration/Deceleration Time (Number #14)
Address: 0544H
0545H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
50
Control
Mode
PR
Unit
ms
Range
1 ~ 1500
Data Size
16-bit
Format
Decimal
Settings
The default value of this parameter is smaller (short deceleration time)
and it is used for deceleration time setting of auto protection.
P5-35 AC15 Acceleration/Deceleration Time (Number #15)
Address: 0546H
0547H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
30
Control
Mode
PR
Unit
ms
Range
1 ~1200
Data Size
16-bit
Format
Decimal
Settings
The default value of this parameter is smaller (short deceleration time)
and it is used for short deceleration time and stops promptly of auto
protection.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)