Chapter 8 Parameters ASDA-A2
8-226 Revision February, 2017
If it does not return to the origin, set PATH to 0.
If it needs to return to the origin, set PATH to non-zero value and
set PABS = ORG_DEF.
B. If the origin is found (Sensor or Z), desire to move an offset S and
define the coordinate as P after moving, then PATH = non-zero and
set ORG_DEF = P-S. The absolute position command = P.
P6-01 ODAT Origin Definition
Address: 0602H
0603H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
0
Control
Mode
PR
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
Value of origin definition:
.31 ~
28
.27 ~
24
.23
~20
.19 ~
16
.15 ~
12
11 ~ 8 7 ~ 4 3 ~ 0
ORG_DEF (32-bit)
P6-02 PDEF1 PATH#1 Definition
Address: 0604H
0605H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
0x00000000
Control
Mode
PR
Unit
-
Range
0x00000000 ~ 0xFFFFFFFF
Data Size
32-bit
Format
Hexadecimal

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals