Chapter 11 Summary of Parameter SettingsC2000
11-5
Pr. Parameter Name Setting Range Default
00-08
Parameter protection password
setting
0–65535
0: No password protection / password entered
correctly (Pr. 00-07)
1: Parameter set
0
00-10 Control mode
0: Speed mode
1: Point-to-point position control mode
2: Torque mode
3: Homing mode
0
00-11 Speed control mode
0: IMVF (IM V/F control)
1: IMVFPG (IM V/F control + Encoder)
2: IM/PM SVC (IM / PM space vector control)
3: IMFOCPG (IM FOC + Encoder)
4: PMFOCPG (PM FOC + Encoder)
5: IMFOC sensorless (IM FOC sensorless )
6: PM sensorless (PM FOC sensorless)
7: IPM sensorless (Interior PM FOC sensorless)
0
00-12 Point-to-point position mode
0: Relative position
1: Absolute position
0
00-13 Torque mode control
0: IM TQCPG (IM torque control + Encoder)
1: PM TQCPG (PM torque control + Encoder)
2: IM TQC sensorless (IM sensorless torque control)
0
00-16 Load selection
0: Normal load
1: Heavy load
0
00-17 Carrier frequency
Normal load
230V/460V
VF, VFPG,
SVC,
IMFOCPG,
IMTQCPG
PMFOCPG,
PMTQCPG
PMFOC,
IPMFOC
IMFOC,
IMTQC
1–15HP 2–15kHz 4–15kHz 4–10kHz 4–14kHz
20–50HP 2–10kHz 4–10kHz 4–10kHz 4–10kHz
60–125HP 2–9kHz 4–9kHz 4–9kHz 4–9kHz
8
6
4
Heavy load
230V/460V
VF, VFPG,
SVC,
IMFOCPG,
IMTQCPG
PMFOCPG,
PMTQCPG
PMFOC,
IPMFOC
IMFOC,
IMTQC
1–15HP 2–15kHz 4–15kHz 4–10kHz 4–14kHz
20–50HP 2–10kHz 4–10kHz 4–10kHz 4–10kHz
60–125HP 2–9kHz 4–9kHz 4–9kHz 4–9kHz
2
575V/690V (Light/ Normal/ Heavy load)
Power/ Control mode VF, VFPG, SVC
1–15HP (575V) 2–15kHz
20–600HP (690V) 2–9kHz
850HP (690V) 2–9kHz
6
4
3