Chapter 12 Description of Parameter SettingsC2000
12.1-00-15
Determines how the motor is stopped when the AC motor drive receives the STOP command.
1. Ramp to stop: the AC motor drive decelerates to 0 or the minimum output frequency (Pr. 01-07)
according to the set deceleration time, and then to stop.
2. Coast to stop: the AC motor drive stops output immediately, and the motor coasts to stop
according to the load inertia.
Use “ramp to stop” for the safety of personnel, or to prevent material from being wasted in
applications where the motor must stop immediately after the drive stops. You must set the
deceleration time accordingly.
If idling is allowed, or the load inertia is large, use “coast to stop”. For example, blowers,
punching machines and pumps
Control of Motor Direction
Default: 0
Settings 0: Enable forward/ reverse
1: Disable reverse
2: Disable forward
Enable the AC motor drives to run in the forward / reverse direction. You can use it to prevent a
motor from running in a direction that would cause injury or damage the equipment.
Digital Keypad Frequency Command Memory
Default: Read Only
Settings Read only
If the keypad is the frequency command source, when Lv or Fault occurs, the parameter stores
the current frequency command.
User-Defined Characteristics
Default: 0
Settings
bit0–3: user-defined decimal places
0000b: no decimal place
0001b: one decimal place
0010b: two decimal places
0011b: three decimal places

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Overload Capacity150% of rated current for 60 seconds
CommunicationDeviceNet
ProtectionOvervoltage, Undervoltage, Overcurrent, Overload, Overheat
Humidity5% to 95% (non-condensing)
CoolingForced air cooling
Control ModeV/F Control, Sensorless Vector Control