Chapter 12 Description of Parameter SettingsC2000
12.1-02-12
10: Low voltage warning (Lv) (Pr. 06-00)
11: Malfunction indication
12: Mechanical brake release (Pr. 02-32)
13: Over-heat warning (Pr. 06-15)
14: Software brake signal indication (Pr. 07-00)
15: PID feedback error (Pr.08-13, 08-14)
16: Slip error (oSL)
17: Count value reached, does not return to 0 (Pr. 02-20)
18: Count value reached, returns to 0 (Pr. 02-19)
19: External interrupt B.B. input (Base Block)
20: Warning output
21: Over-voltage
22: Over-current stall prevention
23: Over-voltage stall prevention
24: Operation mode
25: Forward command
26: Reverse command
27: Output when current ≥ Pr. 02-33
28: Output when current < Pr. 02-33
29: Output when frequency ≥ Pr. 02-34
30: Output when frequency < Pr. 02-34
31: Y-connection for the motor coil
32: -connection for the motor coil
33: Zero speed (actual output frequency)
34: Zero speed including stop (actual output frequency)
35: Error output selection 1 (Pr. 06-23)
36: Error output selection 2 (Pr. 06-24)
37: Error output selection 3 (Pr. 06-25)
38: Error output selection 4 (Pr. 06-26)
39: Position reached (Pr. 10-19)
40: Speed reached (including Stop)
41: Multi-position reached
42: Crane function
43: Actual motor speed higher than Pr. 02-47
44: Low current output (use with Pr. 06-71~Pr. 06-73)
45: UVW output electromagnetic valve switch
46: Master dEb output
47: Closed brake output
49: Homing action complete output
50: Output control for CANopen
51: Analog output control for RS-485 (InnerCOM / MODBUS)
52: Output control for communication cards

Table of Contents

Other manuals for Delta C2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta C2000 Series and is the answer not in the manual?

Delta C2000 Series Specifications

General IconGeneral
Operating Temperature-10°C to 50°C
Storage Temperature-20°C to 60°C
Overload Capacity150% of rated current for 60 seconds
CommunicationDeviceNet
ProtectionOvervoltage, Undervoltage, Overcurrent, Overload, Overheat
Humidity5% to 95% (non-condensing)
CoolingForced air cooling
Control ModeV/F Control, Sensorless Vector Control