DVW Series Industrial IEEE 802.11 a/b/g/n Wireless AP/WDS/Client/Gateway User Manual
3-12
_3
Description Factory Default
Specify the station ID of the device.
Port 1: 246
Port 2: 247
TCP Alive Time
Specify how long the DVW series keeps the TCP session when there is no
TCP activity in specified time. If the time is “0”, then the connection will remain
open.
30
Response Timeout
Specify how long the DVW series waits the response from the serial device. 3000
Retry
Specify the retry time when the time of Response Timeout reached. 3
MODBUS Exception
Specify whether the device send an exception code back to the client when the
response timeout is reached.
Enabled
Slave ID Map
Specify the mapping table of slave ID.
Slave ID Range: Enter the range of real slave ID.
Map ID Range: Enter the range of virtual slave ID which DVW series can
create.
None
Priority
Specify the priority of the serial device. None
3.3.1.2 MODBUS ASCII/RTU Master
If the serial device that connect to DVW series has Ethernet interface, you can specify the station address and
destination IP address in forward table. DVW series follows the forward table to forward data to correct serial
devices.