Chapter 3 Featured Function
3-15
3.3.1.3 TCP Server Mode
In TCP Server Mode, DVW series works as a passive role. DVW series waits the connected requirement from
the host computer or device. The host must send a request message to DVW series for establish the
connection first. After the connection is established, the data can be transmitted between the host and DVW
series.
Description Factory Default
Operation Mode
Display the operation mode of serial port. TCP Server Mode
Alive Check Time
Specify how long the DVW series sends a packet for checking the connection
still alive.
30
Disconnect Time
Specify how long the DVW series keeps the TCP session when there is no
TCP activity in specified time. If the time is “0”, then the connection will remain
open.
3000
TCP Port
Specify the port number of DVW series. 3000