To restore the controller to the default settings
1. Push the button until START EVERY is displayed and the icon appears on
the bottom left of the screen.
2. Push and hold down the button for three seconds.
3. The screen returns to the home screen (clock) and all the default settings are
restored. The current time and date is retained.
18. MAINTENANCE, TROUBLESHOOTING AND REPAIRS
PROBLEM: Valve is not opening automatically or manually
CAUSE: No water pressure
SOLUTION: Open main water supply valve
CAUSE: Faulty solenoid
SOLUTION: Replace solenoid
CAUSE: Flow control handle is turned down
SOLUTION: Open flow control handle on valve
PROBLEM: Valve functions in manual mode but not automatically
CAUSE: Controller is set to OFF mode
SOLUTION: Verify that controller does not show OFF in current time mode
CAUSE: AM/PM not set correctly in current time mode
SOLUTION: Check current time, change AM/PM if necessary
CAUSE: AM/PM not set correctly in start time mode
SOLUTION: Check start time(s), change AM/PM if necessary
CAUSE: Watering restriction or rain delay is preventing watering
SOLUTION: Remove watering restrictions or set rain delay to off
CAUSE: Yellow sensor wires have been cut
SOLUTION: Re-connect sensor wires together with waterproof connector
CAUSE: Sensor is installed and is in a state that prevents watering
SOLUTION: Check sensor and wire splices and verify sensor is normally closed

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DIG 710AP Series and is the answer not in the manual?

DIG 710AP Series Specifications

General IconGeneral
BrandDIG
Model710AP Series
CategoryController
LanguageEnglish

Related product manuals