Troubleshooting / Remedial Action
Current limiter has
activated
This error may trigger at any point during the testing,
programming or firing process. The error points to excessively
high leakage or a short circuit on the channel. The Tagger may
be used to identify the source of leakage using the binary
search technique. If this error occurs after programming the
user will need to reprogram the channel
When the Commander detects a detonator that still has the
internally recorded factory ID, which means that it has not been
successfully tagged, it will trigger the untagged warning.
The Tagger may be used to find the untagged detonator on a
string using the binary search technique.
Once the untagged detonator has been found, it must be
tagged with a delay or location (or both) as per the blast plan.
This error will be displayed either when the user scans a Red
BlastCard when a Yellow BlastCard is expected or vice versa.
The error will also be displayed if the BlastCard is invalid. The
user must scan the correct BlastCard or replace the BlastCard if
it is invalid or not working correctly