There are three methods of operation for the DigiShot
®
Plus 4G Commander System, as detailed below:
With the Basic tagging option, the user will only need to concentrate on the Time value, string number and the
sequence number assigned to the detonator and it is best suited for small, single-primed hole blasts.
It is advised to use only one Tagger per Commander when the Basic Tagging Option is
used. If more than one Tagger need to be used then both Taggers can start at a different
String number and have different Tagger ID’s.
The Advanced Tagging option is used when there is emphasis on both Time and Location but no ViewShot plan is
available for download
The Advanced Mode includes more functionality than the BASIC mode as it allows for multi-primed holes
and time incremental settings.
The user will need to define a hole configuration from the “Site Setup” screen in 4G Setup menu.
With the Planned (P) option, a location and/or the delay is written into the detonator.
The source for the data is received from a plan which is downloaded into the CE4 Tagger via the ViewShot 3D
®
blast design software.