Shutdown diagnostics
To perform shutdown diagnostics:
With the ignition OFF, press and hold the Valet/Program switch.1.
Turn the ignition ON and then back OFF while holding the Valet/Pro-2.
gram switch.
Release the Valet/Program switch.3.
Press and release the Valet/Program switch. The LED flashes to report 4.
the last shutdown for one minute or until the ignition is turned on, as
shown in the following table:
LED Flashes Shutdown Mode
1 Timed out
2 Over-rev shutdown
3 Low or no RPM, low battery
(for voltage and virtual tach modes)
4 Transmitter shutdown (or optional push button)
5 (-) Hood Shutdown (H3/4 GRAY)
6 (+) Shutdown (H3/3 BROWN)
7 (-) Neutral safety shutdown (H3/1 BLACK/WHITE)
8 Wait-to-start timed out

Table of Contents