SERVICE NOTE
Battery Backup
The battery backup is used to retain information programmed in the system (pricing, time, date, etc.) in case of
power interruptions, or any time the main power is off. When the vender is shipped, the battery is connected and
memory is being maintained. Replacement boards will be shipped with the battery disconnected to extend its life. If
the vender is to be stored for long periods of time, disconnecting the battery is recommended. The following steps
will guide you through this procedure.
Open the service door and unplug the main power harness located on the front of the power box.
Locate the main control board mounted on the right side wall.
Remove the screw securing the cover to the board.
The backup system jumper is located just below the battery near the center of the board (refer to figure 2, page
33)
Remove the jumper covering the pins and place it on only one pin for storage.
Reinstall the cover and tighten the screw.
Reverse this procedure to connect the battery.
INSTALLATION AND SETUP INSTRUCTIONS
Open the service door on the right side using the key provided in the coin return cup, or if shipped with a locking
clip, remove the clip and install the lock.
Ensure there is no power to the AC Distribution Box. On venders with a main power switch on the AC Distribution
Box the switch needs to be in the OFF position. On venders with a main power quick disconnect plug on the AC
Distribution Box the quick disconnect plug needs to be unplugged.
Check that all connectors are firmly seated on the control board and at the various components on the service door
(coin mech, keypad, etc.).
Retrieve the main power plug from the hole in the rear of the vender and plug the cord in a properly grounded
120VAC, 15 Amp, receptacle (U.S. and Canada).
Open the service door and apply power to the AC distribution Box (if equipped with a bill acceptor, the acceptor
should cycle twice). The display on the door should scroll message “USE EXACT CHANGE”, fluorescent lamp
should be lit and the cooling unit should start.
If the display scrolls “OUT OF SERVICE”, or the cooling unit fails to start, refer to the PROBLEM SOLVING
CHARTS beginning on page 35.