Page 48
LAPTOP COMPUTER
This example assumes the use of Windows Terminal Mode for communication.
• Open service door.
• Start computer and enter Windows
• Open Accessories
• Select 'TERMINAL'
• Select 'SETTINGS'
• Select 'COMMUNICATIONS'
• Enter the following:
Baud rate- 9600
Data bits- 8
Stop bits- I
Parity- None
Flow control – Xon/Xoff
Select a COM Port
• Select 'FILE'
• Select 'NEW'
• Enter File name (extension must be .TRM)
• Select 'FILE'
• Select 'OPEN'
• Select File just created
• Connect data cable assembly, part #W081, to serial COM Port on computer and J9 on the controller
board.
- J9 is the 3 pin connector referenced by r on Figure 1, page 48.
• Enter a question mark (?) on the computer
• Select 'EDIT'
• Select 'SEND', the program will start sending information to the computer.
• When the download has completed save the file and exit. Disconnect data cable assembly from
computer's serial port and J9 on the controller card.
• Close the service door.
• Exit Windows and shut down computer.