Page 36
MASTER RESET (PASSWORD REQUIRED)
Allows the service technician to restore factory defaults to the machine or reset the Controller Board's memory after
reconfiguring a tray. Since this feature resets sales data care should be taken prior to using. Press the letter "F" on
the key pad and "MASTER RESET * = Y" will scroll across the display. Press the "*" key and the display will read
"PW". Enter the password, the display will read "OK" momentarily and then will return to the idle message.
After using this feature the service technician must go to the SERVICE MODE or TEST MODE and CLEAR
ERRORS.
The table below outlines the results of using MASTER RESET.
ITEM RESET TO
SALES $0.00
NUMBER SOLD 0
TOTAL SALES $0.00
REGULAR PRICES $1.00
HAPPY HOUR PRICES $1.00
COOL DOWN PERIOD CLEARED
HAPPY HOUR TIMES CLEARED
NOT AVAILABLE TIMES CLEARED
DISABLE ITEM ENABLED
DOOR OPENINGS 0
POWER OUTAGES 0
WINNER MODE 0
MACHINE NUMBER 1
IDLE MESSAGE DEFAULT MESSAGE
PASSWORD 0000
DATE/TIME NO CHANGE
MACHINE NUMBER (PASSWORD REQUIRED)
Allows assigning a user number to the machine for audit and/or inventory control requirements.
Press the number "1" on the keypad, "MACHINE NUMBER ##" will scroll across the display (the ## displayed is the
number currently assigned to the machine). Press the "*" key and the display will read "PW". Enter the password,
the display will read "OK" momentarily, then "NUMBER" will be displayed. Enter the new number (numeric field, 5
characters maximum). If the new number is less than 5 characters press the "*" key. After entering it, the display
will return to "SETUP MODE".
SET HAPPY HOUR (PASSWORD REQUIRED)
Allows the service technician to set times and days for Happy Hour operation.
Press the number "2" on the keypad and "SET HAPPY HOUR" will scroll across the display. Happy hour start time,
end time, and days of the week can now be programmed into the system. All times must be entered in military time
format (24 hour clock). Setting Happy Hour is covered in detail in the INITIAL PROGRAMMING section of this
manual. See pages 38, 39, 40, and 41. Press the "CLR" key to return to "SETUP MODE".
SET NOT AVAILABLE (PASSWORD REQUIRED)
Allows the service technician to set times and days for periods, use of the machine is to be restricted.
Press the number "3" on the keypad and "SET NOT AVAILABLE" will scroll across the display. Not available start
time, end time, and days of the week can now be programmed into the system. All times must be entered in military
time format (24 hour clock). Only one not available period of time per 24 hours may be set using this feature.
Setting Not Available is covered in detail in the INITIAL PROGRAMMING section of this manual. See pages 42 and
43. Press the "CLR" key to return to "SETUP MODE".