Symptom:
MIC-GLOVE BOX-MAP LAMP OUTPUT CIRCUIT SHORT OR OPEN
POSSIBLE CAUSES
INTERMITTENT CONDITION
GLOVEBOX-MAP LAMP OUTPUT CIRCUIT SHORT TO GROUND
INSTRUMENT CLUSTER
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, clear all MIC DTC’s.
Turn the Glove Box Lamps on.
With the DRBIIIt, read the DTC information.
Does the DRBIIIt read: Glove box/Map Lamp Output Circuit Short/Open?
All
Yes → Go To 2
No → The condition that caused the symptom is currently not present.
Inspect the related wiring for a possible intermittent condition.
Look for any chafed, pierced, pinched, or partially broken wires.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Glovebox Lamp Switch Harness connector.
Disconnect the Instrument Cluster C1 connector.
Measure the resistance of the Glovebox Lamp Output circuit to ground.
Is the resistance below 5.0 ohms?
All
Yes → Repair the Glovebox-Map Lamp Output circuit..
Perform BODY VERIFICATION TEST - VER 1.
No → Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.
459