Symptom:
FCM-WASHER PUMP OUTPUT CIRCUIT LOW
When Monitored and Set Condition:
FCM-WASHER PUMP OUTPUT CIRCUIT LOW
When Monitored: With the igntion on.
Set Condition: The FCM detects less than 0.05 volts on the Washer Pump Motor Control
circuit.
POSSIBLE CAUSES
INTERMITTENT CONDITION
WASHER PUMP MOTOR - FRONT
WASHER PUMP MOTOR CONTROL CIRCUIT SHORT TO GROUND
POWER DISTRIBUTION CENTER
FRONT CONTROL MODULE
TEST ACTION APPLICABILITY
1 Turn the ignition on.
With the DRBIIIt, clear all FCM DTC’s.
Actuate the Wiper Washers.
With the DRBIIIt, read the DTC information.
Does the DRBIIIt read: Washer Pump Output Circuit Low?
All
Yes → Go To 2
No → The condition that caused the symptom is currently not present.
Inspect the related wiring for a possible intermittent condition.
Look for any chafed, pierced, pinched, or partially broken wires.
Perform BODY VERIFICATION TEST - VER 1.
2 Turn the ignition off.
Disconnect the Washer Pump Motor - Front harness connector.
Turn the ignition on.
With the DRBIIIt, read DTCs.
Does the DRBIIIt display: Washer Pump Output Circuit Open?
All
Yes → Replace the Washer Pump Motor - Front in accordance with the
Service Information.
Perform BODY VERIFICATION TEST - VER 1.
No → Go To 3
532
WINDSHIELD WIPER & WASHER