Symptom:
RIGHT CURTAIN SQUIB 1 CIRCUIT SHORT
When Monitored and Set Condition:
RIGHT CURTAIN SQUIB 1 CIRCUIT SHORT
When Monitored: With the ignition on, the ACM monitors the resistance between the
Right Curtain Squib 1 circuits.
Set Condition: When the ACM detects a low resistance between the Right Curtain Squib
1 circuits.
POSSIBLE CAUSES
RIGHT CURTAIN SQUIB 1 CIRCUIT SHORT
RIGHT CURTAIN SQUIB 1 LINE 1 SHORT TO LINE 2
ACM, RIGHT CURTAIN SQUIB 1 CIRCUIT SHORT
STORED CODE OR INTERMITTENT CONDITION
ACTIVE CODE PRESENT
TEST ACTION APPLICABILITY
1 Turn the ignition on.
NOTE: Ensure the battery is fully charged.
NOTE: For the purpose of this test, the AECM and ORC modules will be
referred to as an ACM.
SELECT ACTIVE or STORED DTC:
All
ACM - ACTIVE DTC
Go To 2
ACM - STORED DTC
Go To 5
NOTE: When reconnecting Airbag system components, the ignition must be
turned off and the battery must be disconnected.