TEST ACTION APPLICABILITY
6 Disconnect the Instrument Cluster C1 connector.
Turn the ignition on.
Measure the voltage between ground and the Door Unlock Driver Right Doors circuit.
Is there any voltage present?
All
Yes → Repair the Door Lock or Door Unlock Driver Right Doors circuit
for a short to voltage.
Perform BODY VERIFICATION TEST - VER 1.
No → Go To 7
7 NOTE: If this a 2 Door vehicle, answer NO to the question and continue.
Disconnect the Instrument Cluster C1 connector.
Turn the ignition on.
Measure the voltage between ground and the Door Unlock Driver Left Rear circuit.
Is there any voltage present?
All
Yes → Repairthe Door LockDriver Left Doors or the DoorUnlock Driver
Left Rear circuit for a short to voltage.
Perform BODY VERIFICATION TEST - VER 1.
No → Go To 8
8 If there are no possible causes remaining, view repair. All
Repair
Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.
465
POWER DOOR LOCKS/RKE
ALL DOOR UNLOCK OUTPUT CIRCUIT SHORT TO GROUND OR VOLT
-
AGE —