TEST ACTION APPLICABILITY
4 Disconnect the Cylinder Lock Switch connector.
Disconnect the Instrument Cluster C2 connector.
Measure the resistance of the Cylinder Lock Switch Mux circuit between the Switch
connector and the Instrument Cluster connector.
Is the resistance below 5.0 ohms?
All
Yes → Replace the Instrument Cluster.
Perform BODY VERIFICATION TEST - VER 1.
No → Repair the Cylinder Lock Switch Mux circuit for an open.
Perform BODY VERIFICATION TEST - VER 1.
486
POWER DOOR LOCKS/RKE