MAINTENANCE AND FAULT FINDING
L025317 Issue 1 March 2011 5-13
3167 Compile-error Internal software
verification has failed.
Please check if all message
parameters are correctly set - if
yes please contact Domino .
3168 Transformation
failed/object out
of bounds.
Objects or parts of
objects are located
outside of the usable
marking field.
Position objects correctly.
3169 Incomplete
object, lacking
external
references.
An object references
an external resource
that is currently not
available.
This normally happens if a text
object references a font that
does not exist in the system.
Change the used font.
3170 Missing marking
parameters.
Parameter set of
object has not been
set.
Ensure that a parameter set is
chosen for all objects.
3171 Invalid marking
parameters.
The values of a
parameter set used by
the current project
are invalid.
Ensure a valid parameter set is
chosen for all objects.
3172 Wrong encoder
direction.
This fault appears if a
message is triggered
to print in continuous
mark mode while the
encoder rotates in the
wrong direction.
Check rotating direction of
encoder.
3173 Encoder too fast. This fault appears if a
message is triggered
to print in continuous
mark mode while the
encoder rotates too
fast.
Ensure the encoder never runs
faster than the project can be
marked. Adjust encoder speed.
3176 Object has invalid
attributes.
Object may reference
another text/barcode
object that does not
exist or uses a
dynamic text tag that
is undefined. This
fault can also appear if
you try to cross-link
multiple text-objects.
Check for invalid attributes.
3177 Failed to compile
referenced object.
General software
fault.
Contact Domino.
Status Message Cause Suggested Action