MAINTENANCE AND FAULT FINDING
5-14 L025317 Issue 1 March 2011
3178 List overflow:
project too large.
The number of
vectors for marking
the project is too
high.
Reduce the number of vectors
by reducing resolutions or
increasing the maximum
vector length etc.
3179 Mark limit
reached.
The predefined limit
of marks has been
reached
This message is displayed when
you print from a file and the
end of the file has been
reached or if you have
counters enabled that have
"Disable Marking" configured
if they reach their end value.
3180 Print failed. General fault. Contact Domino.
3181 DSP failure. The DSP hardware
cannot be contacted
for transferring
vectors.
Ensure that the boards are
fitted correctly.
3182 Print timeout. The current print has
lasted longer than the
timeout for a print as
defined in the system
setup.
Increase the timeout value or
turn the timeout off by setting
the value to 0.
3183 Missing
"printstart"
parameter set
The usage of the
"printstart" parameter
set for the first
polygon in the print
has to be selected.
Define a parameter set with
this name or uncheck this
option.
3184 Barcode Error
Wrong code
length.
The barcode type
needs a specific length
of input data.
Change input data or code
type.
3185 Barcode Error
Unrecognised
code type.
General software
fault.
Contact Domino.
3186 Barcode Error
Invalid
parameters.
The barcode cannot
be calculated with the
parameters given.
Check the barcode-specific
parameters.
3187 Barcode Error
Illegal character in
code.
The barcode data
contains at least one
character that is not
allowed for this code
type.
Check characters in barcode.
Status Message Cause Suggested Action