MAINTENANCE AND FAULT FINDING
L025317 Issue 1 March 2011 5-17
3216 Unknown HPGL
code
The HPGL code of
the vector graphics
file (PLT file) is
unknown.
Make sure that a supported
version of the HPGL file
format is used.
3217 No Message The requested action
cannot be performed
as no message has
been selected in
advance.
Select a message and send it to
printer.
3218 Invalid condition The mark enable
condition (digital
input mask/digital
input value) in the
object properties are
not set properly.
The mark enable condition
(digital input mask/digital
input value) in the object
properties are not set properly
(e.g. the value uses input
channels that have not been
defined in the mask).
3219 Codepoint out of
range
A Unicode character
has been referenced
that is out of the valid
range.
Check the Unicode number of
the character required -
Dynamark 3 only supports
Unicode character codes up to
65535.
3220 Unknown text
format specifier
The dynamic text
format specifier (e.g.
<CLK_YY:x> for
year) is unknown.
Check if invalid specifiers have
been used or the message has
been set up with an
incompatible software version.
3221 Text reference
not found
A text link points to
another text or MRC
object that does not
exist.
Check if an object that is
referenced by another one has
been deleted. Re-edit the
referencing objects to point to
other existing objects or
remove the link.
3222 Invalid text
format specifier
The syntax of a
dynamic text format
specifier (e.g.
<CLK_YY:x> for
year) is invalid.
Check if the message has been
set up with an incompatible
software version.
3223 Isolated accent in
text
A character with
width=0 (typically an
accent that shall be
put upon the
character following) is
not followed by
another character.
Check if there is an accent
character at the end of a line/
message or if the last character
in a line has an invalid width
setting in its font definition
(e.g. by changing the font).
Status Message Cause Suggested Action