MAINTENANCE AND FAULT FINDING
L025317 Issue 1 March 2011 5-19
4000
and
4001
Security Dongle
missing - System
locked
The system is locked
due to the fact that
the advanced or
remote security mode
has been enabled and
no security dongle is
fitted to the laser
controller - only a
service user can now
log into the system.
Insert the Security Dongle into
the controller as the pharma
option has been activated; in
case the pharma option is not
active by intention please
contact the Domino to
deactivate it.
4002 Service Dongle
active
A service user has
logged in to the
system by use of a
service dongle.
Informal message only.
4003 Remote Security
Server not
accessible
The system has been
set up to use a remote
server to authenticate
users - however this
server cannot be
accessed via network.
Check network setup or
wiring. Only the local service
login is possible.
4004 Audit Trail
Backup needed
Some audit trail
entries are older than
the specified limit in
the Dynamark 3
service menu - this is
to remind the
operator to export the
audit trail data from
the action log menu.
(Pharma option only!)
Export the audit trail data from
the action log menu.
4005 Audit Trail
Backup needed -
System disabled
Some audit trail
entries are older than
the specified limit in
the Dynamark 3
service menu - the
system will not
continue to print
until the operator has
exported the audit
trail data from the
action log menu.
(Pharma option only!)
Export the audit trail data from
the action log menu.
Status Message Cause Suggested Action