RS4203 Operating Manual Chapter 7 - Recipe Descriptions
Rev 32, 01/11/13 Copyright © 2013, Tipper Tie, Inc., All rights reserved 45
Item
Operating
Parameters/Features
Description
Valid Range
Default
19
STOP CONVEYOR DURNG
CLIP? (YES/NO)
Enabling this option causes the conveyor
to stop when the RS4203 clip cycle
activates. If set to OFF, the conveyor
continues to run at the stuff-speed while
clipping.
Yes or No Yes
20
SINGLE CLIP BETWEEN
CHUBS (ON/OFF)
This option is used to apply a single clip
between ea
ch chub when creating a chub
chain (i.e. Chub Counter > 1). If set to
OFF, 2 clips will be placed between each
chub. Note: Special hardware is required
for this option.
On or Off Off
21
CONVEYOR DISCHARGE
ENABLE (ON/OFF)
This option is used to enable the
discharge paddle for machines equipped
with the side-discharge conveyor option.
On or Off Off
22
DISCHARGE EXTENDED
LOCK (ON/OFF)
On machines equipped with a side-
discharge conveyor, this option locks the
discharge paddles in the extended
(discharge) position. The recipe item
"Conveyor Discharge Enable" must also
be set to ON.
On or Off Off
23
DISCHARGE EXTEND
TIMER
On machines equipped with a side-
discharge conveyor, this option controls
the amount of time the discharge paddles
remain extended to fully eject the product
from the conveyor. The recipe item
"Conveyor Discharge Enable" must be
set to ON and "Discharge Extended
Lock" must be set to OFF.
0.20s to 5.00s 0.20s
24
DISCHARGE SENSOR TYPE
(ON=PROD PRESENT ON,
OR OFF=PRODUCT
PRESENT)
This parameter sets the TYPE of
SENSOR used to trigger the optional
conveyor discharge paddles. A
secondary trip paddle will normally be ON
when product is present and ready to be
discharged, while an ultrasonic sensor
(for example) may turn OFF as a product
reaches the discharge position. (Only
available on optional discharge conveyor)
ON= Prod
Present
OFF= Prod
Present
OFF
25
GATE CLOSED DWELL
(SEC)
This parameter is used to vary the
amount of time between, the gate starting
to close (i.e. gate-open prox. is no longer
on) and the signal to extend the punch
turning on. Adjustment is made according
to the product being run. (Smaller casing
codes use smaller dwells and larger
casing codes use longer dwell.)
0.00s to 1.00s 0.10s