Dräger Oxylog 2000 Manual
5
of 1
of 1 rating
41 pages
Give review
Manual
Specs
To Next Page
To Next Page
Loading...
Drager
Medizintechnik
Drager
Contents
General
Information
About
the
Drager
Service
Mode
SW
2.xx
3
Definition
of
the
Original
Status
.3
Calibration
Functions.4
Reaction
in
the
Event
of
a
Technical
Error
(TE)
.4
Error
Messages
During
a
Specific
Test.5
Power
Supply
Low.5
Pressure
Low.5
Pressure
High
.5
Mode
Switch
Position
(AirMix/NoAirMix)
.5
Mode
Switch
Position
(IPPV,
SIPPV/SIMV,
CPAP)
(for
Software
Versions
3.xx
and
higher).6
Software
Version
3.xx
is
Incompatible
with
Hardware.6
Tests
in
the
DragerService
Mode
.7
Starting/Exiting
the
Customer
Service
Mode
(CSM)
8
Test
001:
Adjusting
the
Language
.9
Test
002:
Testing
the
Gas
Supply.11
Test
003:
Position
of
the
Pneumatic
Switch
(IPPV,
SIPPV/SIMV,
CPAP;
AirMix/NoAirMix)
12
Test
004:
Buzzer
Test,
LED
Test,
and
LCD
Test
.13
Test
005:
Adjusting
and
Reading
Out
the
Potentiometers
Freq.,
VT,
TI:TE,
and
Pmax.14
Starting
/
Exiting
the
Extended
Service
Mode
(ESM)
15
Test
011:
Calibrating
the
Pressure
Sensors
P-Supply
P-AIRMIX
and
P-LA.16
Test
012:
Calibrating
the
Minute
Volume
Valve
in
No
Air
Mix
.18
Software
Version
2.xx.19
Software
Version
3.xx.20
Test
013:
Calibrating
the
Minute
Volume
Valve
in
Air
Mix.21
5503.160
Oxylog
2000
11/97
Page
1
2
Table of Contents
Table of Contents
1
5503.160 Oxylog 2000
1
General Information about the Drager Service Mode SW
3
Definition of the Original Status
3
Calibration Functions.4
4
Reaction in the Event of a Technical Error (TE)
4
Error Messages During a Specific Test.5
5
Power Supply Low.5
5
Pressure Low.5
5
1.4.3 Pressure High
5
Mode Switch Position (Airmix/Noairmix)
5
Mode Switch Position (IPPV, SIPPV/SIMV, CPAP) (for Software Versions 3.XX and Higher).6
6
Software Version 3.XX Is Incompatible with Hardware.6
6
Tests in the Dragerservice Mode
7
Starting/Exiting the Customer Service Mode (CSM)
8
Test 001: Adjusting the Language
9
Test 002: Testing the Gas Supply.11
11
Test 003: Position of the Pneumatic Switch (IPPV, SIPPV/SIMV, CPAP; Airmix/Noairmix)
12
Test 004: Buzzer Test, LED Test, and LCD Test
13
Test 005: Adjusting and Reading out the Potentiometers Freq., VT, TI:TE, and Pmax.14
14
Starting / Exiting the Extended Service Mode (ESM)
15
Test 011: Calibrating the Pressure Sensors P-Supply P-AIRMIX and P
16
Test 012: Calibrating the Minute Volume Valve in no Air MIX
18
Software Version 2
19
Software Version 3
20
Test 013: Calibrating the Minute Volume Valve in Air MIX.21
21
Software Version 2
22
Software Version 3
23
Test 014: Adjusting and Displaying the Flow.24
24
Test 015: Reading in the Analog Channels
27
Test 016: Testing the Autozero Solenoid Valve
31
Test 017: Displaying and Calibrating the Autozero Offset.32
32
Test 018: Testing the Pressure Sensor Paw and Triggering the Minute Volume Valve.33
33
Test 019: Testing the Supply Pressure
35
Test 020: Testing the Minute Volume Valve (Slow).36
36
Test 021: Testing the Minute Volume Valve (Fast)
37
Test 022: Testing the Differential Pressure Sensor AP and Testing the Flow Measurement
38
Technical Error (TE) List
40
Other manuals for Dräger Oxylog 2000
Operating Instructions
64 pages
Instructions For Use
56 pages
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Dräger Oxylog 2000 and is the answer not in the manual?
Ask a question
Dräger Oxylog 2000 Specifications
General
FiO2
21 - 100 %
Inspiratory Flow
Up to 120 L/min
Type
Emergency and Transport Ventilator
Ventilation Modes
Manual Ventilation
Display
LCD
PEEP
0 - 20 mbar
Related product manuals
Dräger Oxylog 2000 plu
128 pages
Dräger Oxylog 2000 plus
174 pages
Dräger Oxylog 3000
138 pages
Dräger Oxylog VE300
134 pages
Dräger Oxylog 3000 plus
174 pages
Dräger Vapor 2000
76 pages
Dräger Oxy 3000
44 pages
Dräger Savina
132 pages
Dräger EVITA XL
4 pages
Dräger Perseus A500
292 pages
Dräger Fabius Series
38 pages
Dräger Infinity Series
384 pages