DragonWave Inc. 92
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
Redundancy link switch
parameters
When a system is in the process of switching from active to stand-by,
the time that the system needs to wait, to confirm if the stand-by unit
can establish a link, before switching, is provided by the redundancy
link switch parameters. The parameters are different for 1-wire and 2-
wire applications. The example parameter values shown below are
recommended for effective switching and need to be configured at
each end of the link.
FOR PRIMARY AND SECONDARY UNITS-
Sequence, with recommended values:
set redundancy link switch parameters
900 300 80 600 300 80 press Enter
The system responds:
Redundancy Link switch parameters values: 900 300 80 600 300 80
Redundancy status
This command returns the current status of the redundancy system.
Sequence:
get redundancy status press Enter
The system responds (Example):
redundancy mode :primary_hsb_2wire
override mode :manual
peer mode :secondary_hsb_2wire
link is active on :secondary
Redundancy partner
information
This commands returns information about the Horizon redundancy
partner.
Sequence:
get redundancy partner information press Enter
The system responds (Example):
Partner's Information:
MAC Address :00-07-58-00-A2-26
IP Address :192.168.37.38
Redundancy Mode :secondary_hsb_2wire
Receiver RSL :-51.30 dBm
System Mode :hc50_371_256qam
Radio Band :fcc18_1_50
Frequency Bank :txLow
Frequency Index :C8