Advanced Configuration Features
99
Horizon Compact Release 1.01.00 Wireless Ethernet Product User Manual – Volume 2
Required Action Steps
Redundancy override
FOR A PRIMARY UNIT ONLY-
This command determines how the system will respond when a link
failure occurs. “manual” mode is recommended.
Sequence:
set redundancy override manual press Enter
The system responds:
redundancy override mode is set to : manual
Redundancy secondary enet
state
Not applicable to 1-wire mode.
Redundancy status
This command returns the current status of the redundancy system.
Sequence:
get redundancy status press Enter
The system responds (Example):
redundancy mode :primary_hsb_1wire
override mode :manual
peer mode :secondary_hsb_1wire
link is active on :primary
Redundancy partner
information
This commands returns information about the Horizon redundancy
partner.
Sequence:
get redundancy partner information press Enter
The system responds (Example):
Partner's Information:
MAC Address :00-07-58-00-A2-26
IP Address :192.168.37.38
Redundancy Mode :secondary_hsb_1wire
Receiver RSL :-51.30 dBm
System Mode :hc50_371_256qam
Radio Band :fcc18_1_50
Frequency Bank :txLow
Frequency Index :C8
Save mib
Saves the MIB to RAM. Perform this command to save setting
changes to non-volatile memory.
Sequence:
save mib press Enter
The system responds:
MIB saved successfully.