3-8
Distortion Meter Tab
Distortion Meter Tab
Distortion meter
list
PX5 is able to meter distortions or uncharacteristic changes in the waveform of original
signals. Distortion calculations measure the deviation of complex waveshapes from
pure sine waves. Harmonics are measured in accordance with IEC 61000-4-7 Class I.
Continued on next page
Distortion Tab Parameter Name Label
THD
(for A, B, C, D)
Voltage Total Harmonic Distortion
Fundamental
V THD fund
Current Total Harmonic Distortion
Fundamental
I THD fund
Voltage Total Harmonic Distortion Root
Sum of Square
V THD RSS
Current Total Harmonic Distortion Root
Sum of Square
I THD RSS
TID
(for A, B, C, D)
Voltage Total Interharmonic Distortion
Fundamental
V TID fund
Current Total Interharmonic Distortion
Fundamental
I TID fund
Voltage Total Interharmonic Distortion
Root Sum of Square
V TID RSS
Current Total Interharmonic Distortion
Root Sum of Square
I TID RSS
MARK311
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dranetz PowerXplorer PX5 and is the answer not in the manual?

Dranetz PowerXplorer PX5 Specifications

General IconGeneral
BrandDranetz
ModelPowerXplorer PX5
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals